Grab bars for an accessible bathroom
Resistance force
Grab bars need to be capable of resisting 250 lbs. of force
Diameter of bars
The bars should have a diameter in the range of: 1-1/4" to 1-1/2"
Clear space
The space between the grab bar and the walls should be at least 1-1/2"
Locations of applicability
Roll-in showers
- In 36" x 36" stalls, bars should be located on the side wall and the wall opposite the seat
- In 30" x 60" stalls, bars should be located on both side walls and the rear wall
Tubs
- Bars should be located on the rear wall, side wall and side wall opposite controls
Toilet stalls
- Bars should be located on side wall and the wall flush against commode
Grab bars
2" x 4" blocking between wall studs
Fasteners
Finish materials